Hi Thomas,
Yes, this is related to structural beam-end coping. Automatic updating of structural coping is disabled by default, I believe to allow structural members to be moved or modified by non-structural tools if the Structural Application is not loaded.
Please can you key-in the command "expand echo $(STR_DISABLE_COPE_DEPENDENCIES)" just to confirm that it's value is set to the default of 1, this will be diplayed in the message centre.
If that value is changed to 0 automatic updating of copes will be applied but will require the Structural Application to be loaded to succeed.
What are the problem that you have been having with beam end coping?
↧
RE: What are "cope dependencies"?
↧