Clik here to view.

regarding energy simulation results

WE HAVE DONE ENERGY SIMULATION FOR A RESIDENTIAL  BUILDING AND THE ABOVE  ARE THE RESULTS.WE HAVE GOT COUPLE OF INTERNAL FLOORS AND AREA OF EXPOSED ROOF IS VERY SMALL.ANY EXPLANATION SIR THANKING YOU

View Article


Script for reporting number of references

Hi All,I am looking to develop a script (VBA) to report the number of attached reference files and the number displayed.Basically a reference countMain reason is I would like to run an audit on...

View Article


Compound Cells

I do a lot of work for an Insulated Concrete Form supplier.  ie. polystyrene large format Lego bricks which you stack on top of each other and fill with concrete. I want to be able to report back to...

View Article

Datagroup appears to be obsolete, please run dg update - while placing...

Hi All,Every time when I place a plumbing element in Aecosim it is not displaying, rather it gives a error msg "Datagroup appears to be obsolete, please run dg update". then I have upgraded the DG but...

View Article

DRAWING TITLES IN CONNECT EDITION

We made extensive use of the place title function for labeling references in V8i. This seems to be missing in the CONNECT attach reference dialog. Hopefully titles with linked references are still...

View Article


Mstn Ref Attachments versus Revit Links?

Anyone have recent experience with using Revit Links... as well Mstn's Ref files?Haven't looked at Revit's Links for a while. They were seen to be quite crude compared to Mstn's Ref Files.The pain...

View Article

Image may be NSFW.
Clik here to view.

Space frame detailing

Dear All,Anyone can help me to modeling the space frame in AECOsim or ProStructures, with connection as picture below. I upload one drawing with autocad file model in 3d for...

View Article

Links to Aecosim Objects blocked?

Engineering Links seems to have been replaced by Link Sets. OK.Tried attaching a Link to a Wall object using Add Link to Element in Mstn CEU8... the Link was attached but was subsequently detached.This...

View Article


Image may be NSFW.
Clik here to view.

Place User Defined Type

In DG Catalog Editor, I can see 'Foundation | Pile Caps' Catalog Type.  How can I make this type to show up at Place tool?AECOSim SS6 08.11.09.866  SG Dataset.Thanks in advance,OhSung

View Article


BEP requirements: Round tripping?

Interesting to see some big Bentley clients who have been on one or the other CAD/BIM format try to open up and 'liberise' their deliverables requirements.There seems to be some leeway offered to...

View Article

Image may be NSFW.
Clik here to view.

Dimension With Leader ABD Ss6

Is it possible to create a custom dimension style for a leader to have a cell as the terminator.

View Article

Modelling Railway Track

Hello,I have 3D linestrings representing the running edges of a railway line.I would like to turn them into 3D rails.BUT My linestrings have too many vertices - I would like to reduce to about a third...

View Article

Image may be NSFW.
Clik here to view.

REPLACE NEW SPACE LABEL TAGS WITHOUT AFFECTING POSITION OF OLD SPACE LABEL...

Using Aecosim V8i,We have been using a particular space label for room labels annotations, we have made a slight change to that same space label (separated room name, number and area on different...

View Article


Stair re-symbolization in Connect Edition.

I have noticed the re-symbolization of the stairs located on the cut plane seems larger that it was in V8i, which makes our problem worse.   We really don't need to have the stairs re-symbolize, they...

View Article

IFC Pentration

Hi ,After exporting penetration ( opening ) from aecosim ss6 and imported back to ss4 , the opening converted from data group penetration to surface element , how to import the penetration back as data...

View Article


PAZ cell - Schedule values scaled by a 1000

Hi,I used the Aecosim base plate PAZ cell to create a stiffener plate, changed the part and family etc. and added an area and volume variable to it but when i schedule out of data group explorer the...

View Article

Image may be NSFW.
Clik here to view.

Dynamically Adjust Map

Hi,I have placed two Open Mesh Steel Platforms in model..... however the material map for left open mesh was not in orientation with the rectangular platform so I have dynamically rotated and made it...

View Article


Image may be NSFW.
Clik here to view.

Mesh visualization problem

Hi all,I have created a mesh model recently and import into AECOsim, is there any way to only display the texture with colour? Or the triangulation can be switch off somehow?Many thanksMichael

View Article

AECOsim CONNECT Edition - Dynamic Views - Is it possible to create developed...

I am using the latest edition of AECOsim CONNECT Edition, I have used SS4 & SS6. I work in the Civil Engineering, Tunneling & Structural engineer industries, where  a variety of sections are...

View Article

Error settings.xml

Settings file modified by another user, error creating settings.xmlthe solution TF_DATASETNAME=Dataset_XX in the CFG file doesn't work on my system.What else can I try??

View Article