RE: Structural Grid and Building Elevation Marker MISSING on Drawings

Hi Larry. I am using V8i this whole time. I am not certain that this is the cause of it, but recently there have been a project migration to a new Projectwise server. A new datasource and login...

View Article


RE: Structural Grid and Building Elevation Marker MISSING on Drawings

Hi Raymond, Check your Grid Settings to make sure that they will display on each floor when a plan or elevation is created. Also verify that the correct Floor is active or selected before generating...

View Article


RE: Energy Simulator Not Showing Elements in Project Tree

Hi Rafael, Just following up on this post to check if you are still having difficulty with floors not displaying in the project tree?

View Article

Image may be NSFW.
Clik here to view.

Energy Simulator Not Showing Elements in Project Tree

Hello Good Bentley CommunityOnce again I'm having problems with AECOsim Energy Simulator, but now I don't if the problem is me or something is going very wrong in AES.I've been trying to complete the...

View Article

grids in Aecosim

I have tried to create grids in Aecosim but grid bubbles are not visible. does anyone know what could be the problem ? could you please suggest how to go about it.regardsSanjay

View Article


Image may be NSFW.
Clik here to view.

RE: Structural Grid and Building Elevation Marker MISSING on Drawings

Hello Raymond:Do you have 'Show Grid System' turned on in Reference Presentation?  Once you have your drawing view plan opened, right click on one of the elements in it and select Reference...

View Article

RE: Structural Grid and Building Elevation Marker MISSING on Drawings

Tried it. Still no luck.

View Article

RE: Structural Grid and Building Elevation Marker MISSING on Drawings

The show grid system is checked, but the grid still not showing.

View Article


RE: grids in Aecosim

Sanjay, I have not been able to reproduce your issue. What version of AECOsim Building Designer are you using? Also, I recently saw an issue where a "mask" level was covering up grid bubbles and...

View Article


RE: Space Label - Text Repeating

Hi Raymond, One thing to verify first is that the label is properly defined under the Manage Data Group Annotation Cells from the top menu: Building Designer > Manage DataGroup Annotation Cells

View Article

RE: Structural Grid and Building Elevation Marker MISSING on Drawings

I see, from what I can tell seems that you have all the proper settings in order for the grid to display, is this happening on a particular file? And is it reproducible outside of Project Wise ?

View Article

RE: New discipline in Datagroup Explorer

Hi Davulsukur,Please go through the following Wiki. Hopefully this would help you.Adding a Type to a DataGroup Catalog FilterTathagata.

View Article

New discipline in Datagroup Explorer

Is it possible to create a new discipline in the Datagroup explorer?So a Civil Engineering one (for example) to go along with Structural, Architectural etc.

View Article


RE: Space Label - Text Repeating

Hi Gerard, How do i go about properly defining the label? On another floor, they are all showing up correctly except in a few locations where the room tag name would still show up 3 times.

View Article

Image may be NSFW.
Clik here to view.

Space Label - Text Repeating

How can i get the room name to show up just once? Preferably on line 3 (bottom line). Thanks.

View Article


RE: Space Label - Text Repeating

When the Composition Model is exported into the local drive outside of Projectwise, the Drawings and Sheets created locally are showing up normal. Could it be the dataset or seed file from PW?

View Article

RE: Structural Grid and Building Elevation Marker MISSING on Drawings

This is happening on all files. Drawings produced outside of PW is coming out normal. Could it be a dataset issue or a problem with the composition or drawing seed file?

View Article


RE: CR: AecoSim Energy Simulator integrated with AecoSIm Building Designer

bump

View Article

Image may be NSFW.
Clik here to view.

CR: AecoSim Energy Simulator integrated with AecoSIm Building Designer

BIM v BEMRan across these DDS-CAD vids (the vids are are in English)... it struck me that the base information for energy modeling should be an integral part of the initial space programming...

View Article

RE: Aecosim

In most situations user and interface do not need to change, both of these are removed from our CONNECT Edition products.Each project that you work on requires a project to be created to store the...

View Article