Quantcast
Channel: OpenBuildings | AECOsim | Speedikon | Forum - Recent Threads
Browsing all 4872 articles
Browse latest View live

RE: Retouching plans from the drawing composition manager

If you are using BV/DV's, there are two tools for this kind of thing;- Hide and Copy Hide in the right click menu. Would be good to get your feedback on how these tools could improve... and what is...

View Article


Retouching plans from the drawing composition manager

Hello good Bentley Community,I'm turning to you guys because I have a question about plan creation, let me explain.When I define a section or elevation or plan from the drawing composition manager, it...

View Article


RE: Creating New Catalogue Type

Thanks Koert. so where exactly are these XML stored in the dataset...I mean the path. I need to create a new type for Door (Access Panels) and wall (demountable wall) I look forward to hearing from you...

View Article

RE: Creating New Catalogue Type

That depends on your configuration. The Catalog Types and DataGroup definitions are usually located in "datagroupsystem". The actual Catalog Items (and custom catalog types and catalog type extension...

View Article

Image may be NSFW.
Clik here to view.

Creating New Catalogue Type

Hi all,as illustrated in the image below, i am trying to create a new catalogue type but my OK button is greyed out. why? Also how can copy definitions from one catalogue type to anotheri look forward...

View Article


RE: CR: TFREMOVE Enhancements

"dg modify data", click element, Right click catalog entry, Delete, OK is probably what you're looking for, but I agree it would be nice to have an icon for it. Bentley changed modify datagroup to...

View Article

RE: Cached views showing as out of date

This is extremely frustrating now and VERY time consuming. I have 25 drg sheet files to issue and each one i open gives me the message that "child reference cache is out of date" on one or more...

View Article

Cached views showing as out of date

I am currently caching my dynamic views as per the best practice wherever possible however iam finding that sometimes (not all) as soon as i cache a view it shows as being out of date and the view...

View Article


RE: Referencing of DV files

If this is true then that is absolutely ludicrous!!! I'm not in the position to go and re-create hundreds of DV files unfortunately. Time constraints on the job just wont allow it nor should i have to.

View Article


RE: CR: TFREMOVE Enhancements

Nope. "dg modify data" does not remove the DG data from walls or slabs in SS5. Ideally, it should strip the dg info and leave a TF Linear or Slab Form.

View Article

Image may be NSFW.
Clik here to view.

CR: TFREMOVE Enhancements

1. TFREMOVE should be a part of the DataGroup System toolbar. Add+Modify and Remove/Delete are actions that are closely related. TFRemove should be just as prominent as Add and Modify, not relegated to...

View Article

RE: Referencing of DV files

It would be good to check and submit a TR/SR.

View Article

Referencing of DV files

I have created multiple DV files from a model which are then referenced into sheet files. The DV file appears correct in terms of positioning within the DV file itself (when i reference the grid file...

View Article


RE: Long File Opening times

Great news Rafael! It would have taken me some time to uncover that!The Building Designer (pull-down menu) - Verify Configuration command is a good tool to use for this sort of thing. I'm glad you...

View Article

Long File Opening times

Hello good Bentley CommunityI'm having a problem with my file agility, when I open a 3d model in AECOsim the loading times can take up to 10 minutes, and if I start handling references it takes a long...

View Article


RE: Stair construction AECOsim(08.11.09.863)

I agree. It's a super short stair. The only thing I'm trying to change is the tread thickness and I do not see any constraint related messages. Did I stumble upon the minimum height for stairs?

View Article

Stair construction AECOsim(08.11.09.863)

I'm creating stairs with validation turned on and I'm running into a problem when I attempt to modify the stair after it is placed. I'm starting with a Steel Egress stairs, all default settings except...

View Article


RE: AECOsim Electrical SS6

The UK symbol library BS EN60617 / BS 1635 does not contain the space type definitions as the US symbol library ANSI Y32.9-1972. So, what is shown in the workbook is incorrect for the UK dataset. This...

View Article

AECOsim Electrical SS6

is anyone in the UK using AECOsim Electrical for placing symbols, raceways etci ?if so which version are you using?i have spent some time going through the on demand learn workbook for AECOsim...

View Article

RE: WHY I CAN'T EXPORT TO ISM ?

Hi Nguyen, Do you mean that after clicking the Export button the entire AECOsim Building Designer application closes without any warning or message?

View Article
Browsing all 4872 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>