IFC import

I'm importing a multi-storey structural model from IFC. On all storeys but one the imported file shows the holes in the slabs for stairs, lifts, risers etc but on one floor there only appears a solid...

View Article


RE: Dynamic Views - True Sections

I've seen a similar thread from a few weeks back and the conclusion was that only 90° steps in a section line, and always looking in the same direction, were directly supported. If you want to look...

View Article


RE: Dynamic Views are slow and complicated

Yes. There are tips and tricks in Marc Thomas's Looking under the bonnet blog. Briefly, to speed things up, the recommendation is to use CVEs as far as possible. Limit the use of Drawing Rules type...

View Article

Dynamic Views are slow and complicated

I am trying to use the dynamic views on my current design project for a Waste Water Plant upgrade.  It took a while but I figured out how to use them and setup the dataset so my drawings look like they...

View Article

RE: Dynamic Views - True Sections

Hi John, we currently do not have the ability to create DV sections along a line string or alignment centreline. Please can you file a Service Request asking to be linked to: Enhancement 488731:Users...

View Article


Dynamic Views - True Sections

It there a way to create a true section with Dynamic Views?  Similar to a Civil profile where the length of your section line in the same length as the Section view.  Instead of looking in one...

View Article

RE: download AECOsim

Hi, please can you confirm that you are downloading from our Fulfilment Center?

View Article

download AECOsim

Hi, i have tried to download AECOsim in different version but when it finish, say that "the connection with the server has been lost", i have tried three times and say the same. i already downloaded...

View Article


RE: Exclude Level Filters

Hi Henry, This isn't something I normally work with, but let me see what I can track down for you.

View Article


RE: Exclude Level Filters

Hi Henry, OK, it looks like we store each set of level filters in its respective level library, by default located under C:\ProgramData\Bentley\AECOsimBuildingDesigner V8i...

View Article

Image may be NSFW.
Clik here to view.

Exclude Level Filters

AECOsim Building Designer SS6V - 08.11.09.829Hi all,can someone please tell me if a configuration variable exists to exclude level filters from your dgn file. for example, the levels shown in the image...

View Article

RE: Issues with Rectangular Duct Takeoffs - ABD 829

Hi Jeff, Thanks for confirming. I couldn't seem to reproduce it so just wanted to be sure!

View Article

Image may be NSFW.
Clik here to view.

Issues with Rectangular Duct Takeoffs - ABD 829

I've been having quite a few issues with trying to place a rectangular takeoff on the bottom of a duct.  The main duct is 1500mm X 900mm and the takeoff branch I want is 1600x450 (see top image).As you...

View Article


RE: customized section for structrual memeber in AECOsim??

hej Paul, I am working for the harbour department, we deal a lot of harbour projects with sheeppile walls. different from other departments, we need the sheet piles to be modeled quite detailed up for...

View Article

Image may be NSFW.
Clik here to view.

customized section for structrual memeber in AECOsim??

Hej guys,this is an old topic I brought it up again as I never find the prefect solution.....I managered to use Shapestemplate.xls file to ceate section xml files for structrual members in AECOsim.but...

View Article


Downloading Software

i have downloaded bim081109866en.exe (aecosim ss6 uk/gb/) there are 3 versions avaliable in the download site all dated the same. I have chosen the one that is closest to the top of the list. i think...

View Article

RE: Exclude Level Libraries

Henry,The leevl libraies are attached to support the part & family symbology, without the dataset levels being present you will run into problems cretaing Dynamic Views with the correct symbology....

View Article


Image may be NSFW.
Clik here to view.

Exclude Level Libraries

AECOsim Building Designer (SS6)V - 08.11.09.829AECOsim by default comes with some predefined level libraries for architecture, structural, etc and whenever you open any dgn file in this version, the...

View Article

Image may be NSFW.
Clik here to view.

RE: Downloading Software

Hi David,The correct download on the Fulfilment Center for GB is highlighted below, this includes the application and the regional dataset that is shown in brackets:The datasets are all available as...

View Article

RE: ABD SS6 - Updating dynamic views

Hi Borja, I'm not sure if there's anything on the horizon in CONNECT Edition that would lead down this path, but I would suggest logging a Service Request with a description of what you envision so...