Quantcast
Channel: OpenBuildings | AECOsim | Speedikon | Forum - Recent Threads
Browsing all 4872 articles
Browse latest View live
↧

RE: AECOSim Slow to start and hangs if project is changed between files?

Rodger, As a test only, what happens if you change your Project to Building_Template_US or one of the other delivered Projects? Your file won't look right, but it will test opening time. Just a...

View Article


RE: AECOSim Slow to start and hangs if project is changed between files?

Larry, Unfortunately changing the Project or the Interface load out changes the hanging of the program between the file changes. Its very odd. I will be looking to reinstall MS out of the box without...

View Article


RE: AECOSim Slow to start and hangs if project is changed between files?

Rodger, just to check the version, are you on SS6 (.829) or SS6 Update 1 (.866).

View Article

AECOSim Slow to start and hangs if project is changed between files?

So we are using SS6 and most things are fine, but if we are to "Close" a file and then go to open another file, even the same file again, MS hangs for some time, sometimes up to 10 minutes if left, but...

View Article

RE: About AECOsim BD, How to customize the definition property?

Hi Zhengpeng, I suggest that you try this on a released version of AECOsim Building Designer V8i if you haven't, since the Connect Edition is not officially released just yet.

View Article


Image may be NSFW.
Clik here to view.

RE: Energy Simulator Not Showing Elements in Project Tree

Thank you again Larry for your help.I'm attaching a pìcture with the data of my versionBest RegardsRafael

View Article

CR: Floor Manager Rules-based Logic

Is there a way to define the floors by elevation only?The silly way Floor Manager works is based on having to define a floor elevation from the bottom AND a Floor-to-Floor height. This creates a...

View Article

RE: About AECOsim BD, How to customize the definition property?

Hi Gerard,  I do the same things in  AECOsim Building Designer V8i(SELECTseries 6 Ver. 08.11.09.866) , this is the latest versin. but the result is the same as what  in CONNECT Edition, nothing happen,...

View Article


RE: AECOSim Slow to start and hangs if project is changed between files?

Hi Marc, It is .866 version. Is there a known issue with .829 similar to this?

View Article


RE: AECOSim Slow to start and hangs if project is changed between files?

Rodger, AECOsim Building Designer and MicroStation load into different directory structures and should not be linked in any way besides some shared library files. I don't see how reloading MicroStation...

View Article

RE: AECOSim Slow to start and hangs if project is changed between files?

Sorry Larry I meant I will reload Aecosim again to see if its out of the box set up has the lag for switching files.

View Article

RE: AECOSim Slow to start and hangs if project is changed between files?

Ah...that would make sense. Thanks!

View Article

RE: ABD upgrade is MS licence still good?

Laughing Jack, AECOsim Building Designer (ABD) and MicroStation use different licenses. MicroStation will not use a AECOsim Building Designer license. However, AECOsim Building Designer SS6 Update 1 -...

View Article


RE: ABD upgrade is MS licence still good?

So then we should uninstall the old MS-V8i because it's no longer licensed and we're being charged xtra for it??

View Article

RE: ABD upgrade is MS licence still good?

Yes, I would uninstall MicroStation because the two products require their own license. You can, however, use Bentley View in order to open any file Read-only, if you want. See Marc's response to this...

View Article


RE: ABD upgrade is MS licence still good?

Hi Laughing Jack, For question regarding licensing purchase or your current Select contract status, I suggest that you contact either the Licensing group or your Account Manager since they will provide...

View Article

RE: About AECOsim BD, How to customize the definition property?

Zhengpeng Chen, I see, I'll look into this and see if it can be reproduced on a released version of AECOsim.

View Article


RE: ABD upgrade is MS licence still good?

We have already made the purchase, now I'm discovering all the things they didn't tell me when I did. I have 5 people working in MS now, we aren't viewing files we're creating files. By licensing...

View Article

RE: ABD upgrade is MS licence still good?

If we have to completely migrate to ABD, is it possible to bring our custom tools, line types, toolbars. etc.?

View Article

RE: ABD upgrade is MS licence still good?

I'm sure it depends on what they do...but AECOsim Building Designer is built on Bentley's Power Platform which should include any and all MicroStation commands.

View Article
Browsing all 4872 articles
Browse latest View live