display rule prevents elements from unifying

$
0
0

I have a display rule set-up on my forward view to hatch spaces based on their criteria, this generally works fine, however there are 2 issues. 

1st is that when I apply the display rule, unification of elements doesn't work when the view is cached.  

2nd, is that 2D cells mask out the hatches. 

  this image shows the drawing view without the display style applied

  this image shows the same but with the hatch display rule applied, note additional lines in wall, and the hatch masked by the door cell


AECOSim Drawing Extraction Manager Output Folder

$
0
0

Is there a way to have the Drawing Output Folder updated for multiple extractions and multiple drawings in batch?


Thanks.

Aecosim / Electrical / Raceway hanger brackets not scaling

$
0
0

Hi

      I'm having issues when trying to place raceway hangers. The hangers are being placed correctly but the brackets are not scaling correctly to the selected size. I'm using the uk dataset the hanger selected is a Threaded M8 rod - bracket 1. strut profiles KHA 500mm.

Regards

                    Keith

ABD Ss6 best workflow for removing installed Part and Families

$
0
0

I would like to know of the approach to take to remove Part and Families that come with ABD, this would also include the levels too. Am I able to keep some or do I need to start from scratch. The work I do is in the mining/materials handling and I only use aecosim for modelling steel structures. I've tried modelling concrete with the structural design tools but keep reverting back to solid modelling for its ease of use.  

Thanks

Aecosim Mechanical : Copy function with the same intelligence than Move Function

$
0
0

Hi, I have a suggestion for Aecosim Developper,

It would be really nice to make a "copy" command with the same properties as the "Move" function!
What do you think, it would be really practical for duct and pipe with slope !!

thanks

joel


CONNECT Edition - Configuration Changes

$
0
0

Hi,

Can anyone help with how you get the install to change the desktop shortcut as per below from the "CONNECT Edition - Configuration Changes" document?

Tensor’s administrator configures the Bentley application installation to install the application desktop shortcut to include the command line argument “-WR\\Tensor\MicroStation\Configuration\”.

I want to be able to create a deployment that automatically adds the argument to the shortcut.

Cheers

Jonathan

Mechanical: How to transfert parameters of Aecosim to my own parameters and transfert to IFC

$
0
0

Hi,

My customer need a special pset, he use solibri and he would like to filter information with this software, but only on his pset (gio)

I would like to copy some elements of properties(Parameters) to my properties (GIO) and export to IFC .... see my picture 1

by default In Solibri all is mapping in "parameters" picture 2

someone can help me

thanks

picture 1

picture 2

Labels from spaces does not appear when creating Drawing Extraction

$
0
0

Hi,

I am using Aecosim SS6 Ver. 08.11.09.829 Via Projectwise SS4 I am working on a MEP project and I am now creating sheet. I am using Drawing Extraction Manager to create my sheet and I used the "Process a Reference Group Model" option but when I open my extracted file, space labels are not included. What am I missing?

Thanks,

Vince


Putting AU dataset on the network Ss6

$
0
0

I'm having a little trouble trying to config abd to read the dataset from the network. I have followed along to the Quickconfig guide but I must be misssing something.

From what I have gathered a simplified version of the hierarchy tree is like this, I'm just including the STF_DATASET but the others are children of _TF_DATASETS too.

My problem is in BuildingDesigner.cfg the following statements are declared.

TF_DATASETS : $(_TF_WORKSPACEROOT)BuildingDatasets\

STF_DATASET : $(TF_DATASETS)$(STF_DATASETNAME)\

So in my Project config file I assign 

TF_DATASETNAME = Dataset_MyCompany

Which points STF_DATASET to C:\ProgramData\Bentley\AECOsimBuildingDesigner V8i Ss6\WorkSpace\BuildingDatasets\Dataset_MyCompany. This is obviously not what is intended to happen

Detailing Symbol Styles Connect Edition

$
0
0

Hi,

We redrew the DetailingSymbolStyles.dgnlib in version ss6 which works fine but when we copy it forward to the connect edition it doesn't read it.

Where should the file be stored in our network version and how do you get it to read it.

I have put it everywhere that I can think of and removed the default installed one but it still uses the standard setup.

Is there a different file that we need to bring forward as well?

Cheers

Jonathan

'Flat File' not work in ABD Why?

$
0
0

Error message 'This tool cannot be used with column grid elements' why?

Detach instance data to USER elements - ABD CONNECT UPG2

$
0
0

Hi there, I'm trying to Detach instance data on a beam created from a solid, using the Detach tool but it deletes Family and Part info but doesn't delete Datagroup name and catalog. I can see it in the Building Element Info dialog.

Process: I first created the solid (curved "beam"), then I used Attach tool convert it into a catalog beam with Datagroup info, and when I want to modify datagroup data I cannot do it because "the element already has instance data".

1.- How can I delete ALL instance data from an element created this way?

2.- How can I apply Datagroup data from an element to my "USER" element?. Using Schedules only works with APP elements, not with USER elements.

Thank you

Grid System Missing on my PW sheets

$
0
0

Hi Again,

I am trying to compose some drawings on our MEP project,  But the Grid system is missing and some of my main references are missing too (Architectural and Structural). I am using AECOsim  SS6 and PWise SS4. 

Regards,

Vince Francisco

ifc export - objects not being mapped/categorised properly

$
0
0

i am exporting to ifc and generally this is going smoothly, however I have a series of elements which will only export as generic models/objects. 

Main culprits seem to be slabs, compound walls and doors, though general cells etc also. around 50% of my geometry.  

Single walls export no problem and when opened in solibri or navisworks are grouped as 'walls'. Compound walls however only import as generic models, example below. 

   

Opening penetration invisible in IFC files !!!

$
0
0

Hello,

I've to give my penetration file to Architectes (allplan and revit) for coordination. I use Opening of Aecosim, I place Opening on architecture in reference (IFC from Revit)

I've no to choice to transmit in IFC file ... in my drawing all are there but after exportation in IFC ! there are nothing !!!!

DGN

IFC file in SOLIBRI

thanks for help


AECOsim Energy Simulator for beginners

$
0
0

Hi All,

Could anybody share tutorials how to use AECOsim Energy Simulator form the beginning please?

I used to work with Hevacomp and IES before. It looks similar but I need little help how to start work with it.

Thank you

Structural Data in Schedule

$
0
0

I'm trying to make a rebar schedule for concrete beam/column and noticed that 'structural data' Group is not available. Is there any way to get those attributes in schedule?

AECOSim SS6 08.11.09.866 (I can see it from CONNECT version)

Thanks in advance.

OhSung

CH2M is now Jacobs

Create plan views has STOPED working!

$
0
0

For the last couple of weeks I am unable to create any floor plans from the model using `create plan views` or from any other method.    The Create Plan Views icon, gives you three options and all of them produce the same.  Either a blank black CAD screen or a grayish empty drawing screen set to an isometric view.  I am not doing anything different than I have in the last 5 years but despite a reinstall it hit and miss but definitely getting worse.  Any ideas?

Device hookup on slope pipe going wrong

$
0
0

Hi,

I'm working on sewer network,

the hookup function running well on piping when the slope 0, but when I've slope (1.5%) is completely wrong !!!

can we hope for an improvement for future update ?

thanks

Piping - double elbow 45°

$
0
0

Hi,

I'm working sewer network, rule of art says that it takes 2 elbows of 45° for create 90° angle (see catalogue saintgobain...)

someone can help me because is really complicate and long to manage this !

it would be interesting if the function "connect Ducts/pipes" could offer the choice between an elbow of 90° or two 45°

and how to set as default autofitting option ?